SCVMM error adding cluster from untrusted forest

Hi all ! 

 

Would like to seek some help to the issue faced below, for SCVMM, when trying to add from a untrusted forest. Has anyone faced this issue before ? 

 

andyjad_0-1656405082307.png

 

Thanks in advance 🙂 

1 REPLY 1
rachelgomez_123
Level 3 Contributor

To resolve this issue, complete the steps below:

Test using the following commands in an elevated command prompt (run a CMD prompt as administrator):

Console

Copy
winrm e wmi/root/cimv2/Win32_PerfRawData_Tcpi
Examine the result:

p_NetworkInterface
WSManFault
Message
ProviderFault
WSManFault
Message = HRESULT = 0x800007D0

Error number: -2147023537 0x8007054F
An internal error occurred.

Console

Copy
wmic path Win32_PerfRawData_Tcpip_NetworkInterface get *
Examine the result:

ERROR:
Description =

Perform the steps documented in the following knowledge base article to rebuild the performance counters:

2554336 How to manually rebuild Performance Counters for Windows Server 2008 64bit or Windows Server 2008 R2 systems

Remove the partially added cluster and re-add the same cluster once again.